Protecting e-mobility charging systems

DEHN products

  • Protect the charging infrastructure,
  • Protect the electric vehicle during the charging process,
  • Increase the availability of the charging posts,
  • Meet normative requirements.

Here you will find an overview of the relevant products for a comprehensive surge protection concept for electromobility.

Recommended products

E-Mobility - recommended productsNSHVLadesäuleDatenseiteDatenseiteLadesäuleDatenseiteErdung, Potentialausgleich

A - Low-voltage main distribution board of smart transformer sub-stations

DEHNvenCI

For protecting the power supply at the main feeder. Spark-gap-based combined arrester with integrated lightning current carrying backup fuse and low voltage protection level UP ≤ 1.5 kV (including backup fuse). Extinction of main follow currents up to 100 kArms.

DEHNguard ACI

Alternative: For protecting the power supply.
Type 2 surge arrester with integrated ACI switch/spark gap combination which allows safe dimensioning. Cross-sectional area of only 6mm² Cu is always sufficient.

VA NH00

Alternative: Type 2 arrester with integrated backup fuse in NH-00 design.

B - Charging post

AC-supplied charging posts

DEHNvap EMOB

Our recommendation:

Combined lightning current and surge arrester to protect power supply systems in the charging infrastructure.

Time-proven spark gap technology for three-phase TT and TN-S systems (3+1 configuration). Type 1 + type 2 + type 3 protective effect up to the terminal device.

 

DEHNshield ZP

Alternative:
Type 1 and type 2 spark-gap-based combined arrester for three-phase TT and TN-S systems. To be snapped on 40 mm busbar systems.

DEHNguard ACI

Alternative: Type 2 arrester with integrated switch/spark gap combination. Can be used without additional backup fuse.

DEHNcord 3P TT 275 FM

This compact type 2 and type 3 surge arrester meets all relevant standards and offers reliable protection. With its many different mounting options, it fits into almost any gap. Our recommendation for use in wall boxes.

DC-supplied charging posts

DEHNguard ME DC

Type 1 and type 2 combined arrester for DC current characteristic up to 950 V. With powerful DC switching device DCD.

DEHNguard SE DC

Alternative:
Type 2 arrester for DC current characteristic up to 900 V. With powerful DC switching device DCD.

C - Information technology

BLITZDUCTOR XT

Space-saving TYPE 1 combined arrester module with LifeCheck for protecting 1 pair.

BLITZDUCTOR SP

Space-saving TYPE 2 surge arrester module for protecting 1 pair.

Base part BXT BAS

Base part for BLITZDUCTOR protection modules.

DEHNpatch

Universal type 2 arrester for Ethernet and structured cabling systems up to 250 MHz.

D - Earthing and equipotential bonding

Mesh mat

Protection against step voltage – stainless steel (V4A)

Connecting clamps

For mesh mats

Round wires

e.g. 10 mm round wire

Earth rod

Stainless steel (V4A)

Alternative:
Galvanised steel (Part No. 625151)

Connecting clamp for earth rods

Stainless steel (V4A)

Alternative:
Galvanised steel (Part No. 610010)

Anti-corrosion tape

To be wrapped around aboveground and underground connections and for use in the ground according to DIN 30672.

back to top