Extremely good – down to the finest detail.
The DEHNventil M2 series
With the DEHNventil M2 series, you're getting maximum performance in the smallest installation space. Flexible to use, the combined arresters protect industrial low-voltage switchgear reliably and without interruption with a compact single module. The tested Type 1 + 2 + 3 combined arresters in accordance with EN 61643-11 provide lightning equipotential bonding, surge protection and terminal device protection in just one device.
Technical details
What makes the
DEHNventil M2 series stand out
extremely powerful
The DEHNventil M2 series impresses with maximum power density: A high impulse current and short-circuit-current resistance of 100 kArms, combined with a modular design concept – with a size of just 4 standard DIN modules.
extremely quick
The integrated RAC spark gap technology sets unrivalled standards: Compared to other spark gap technologies, it quickly reduces lightning currents to a level that is safe for the downstream installation.
extremely universal
Available for all standard system configurations (multi-phase, single-phase), space-saving and flexible installation. The DEHNventil M2 series is the ideal "all-in-one solution" for a wide range of applications.
Technical features at a glance

1. Easy module replacement
2. Remote signalling contact for condition monitoring
3. Maximum width: 4 standard DIN modules
4. 2 PE connections for improving the protection level
A power density that is unrivalled
Never before has so much power been possible in so little space:
Suitable for all classes of LPS
The Type 1 + 2 + 3 combined arrester is therefore the first choice, particularly in industrial environments and for increased technical requirements.
Modularity
The plug-in block enables quick and safe replacement. All phases are replaced simultaneously.
Application in industry
Can be used in systems with short-circuit currents of up to 100 kArms.
Lower system load
The fast RAC technology largely isolates the downstream system from harmful lightning currents.
Safe and flexible installation support
Serial wiring with optionally available pin connection terminal for flexibility and safety during installation.
Highest mechanical load capacity
even with extreme lightning current loads such as direct strikes into the building (Itotal = 100 kA for lightning protection class I).
Surge protection in a
compact design
One series, many options

Easy installation
More room in the switchgear cabinet means easy installation and wiring of the DEHNventil, as well as adjacent components. The option of lateral installation helps you to maintain a cable length of 0.5 metres. 180°-rotated installations are also possible.

Optimal use of space and lower costs
The small space requirement of the DEHNventil can save costs if a smaller control cabinet is sufficient. With a width of just 4 standard DIN modules, the combined arrester frees up space for additional components.
Good to know: The DEHNventil M2 series protects terminal equipment within 10 metres of cable length. The costs associated with additional devices and their installation are done away with.
Can be used in all system configurations
The right solution for every requirement
Discover the diversity of the DEHNventil M2 series.
The surge arresters are available for use in TNS, TNC, TT and TN systems.
/de.hn/store/f/57668598/HDVORSCHAU/956405.jpg)
956405
DEHNventil M2 TN-S
Four-pole, modular combined arrester for TN-S systems, Type 1 + 2 + 3. Spark-gap-based, with plug-in protection module and Rapid Arc Control (RAC) for maximum system availability.
/de.hn/store/f/57668556/HDVORSCHAU/956305.jpg)
956305
DEHNventil M2 TNC
Three-pole, spark-gap-based, Type 1 + 2 + 3 combined arrester, consisting of a base part and a single plug-in protection module. Maximum system availability due to rapid arc control (RAC) spark gaps.
/de.hn/store/f/57668641/HDVORSCHAU/956205.jpg)
956205
DEHNventil M2 TN
Multi-pole, modular combined arrester for single-phase TN systems, Type 1 + 2 + 3. Spark-gap-based, with plug-in protection module and Rapid Arc Control (RAC) for maximum system availability.
/de.hn/store/f/57668618/HDVORSCHAU/956315.jpg)
956315
DEHNventil M2 TT
Multipole, spark-gap-based, modular DEHNventil combined arrester type 1 + type 2 + type 3 according to EN 61643-11, consisting of a base part and a plug-in protection module.
Installation video
The installation video provides you with the required tools, step-by-step installation instructions and an insight into the technical features.

RAC spark gap technology
Know-how you can rely on
Speed is safety: Because the RAC (Rapid Arc Control) technology reacts extremely quickly and allows less residual energy to pass through, downstream systems are protected and the service life of the connected devices is thus extended. With RAC technology, electric arcs are fed into the arcing chambers at lightning speed, split into individual sub-arcs and quenched.
Want to find out more about RAC spark gap technology? We will gladly show you further explanations of the function and advantages of this technology.
More on the technology
Applications of the
DEHNventil M2 series
Reliable protection for power supply
The DEHNventil M2 series provides optimum protection for low-voltage main distribution boards. In buildings and facilities with important infrastructure, the surge arresters provide reliable surge protection for office complexes, shopping malls and medical care centres. In production processes and industrial applications, the DEHNventil M2 series protects critical processes and ensures uninterrupted production. In addition, surge arresters of the DEHNventil M2 series are essential components in energy-generating systems such as hydrogen electrolysis plants and other pioneering technologies. In the railway power supply sector, surge arresters make a significant contribution to the availability of digital interlockings, level crossing safety systems and point heaters.



FAQs
Where is the optimum field of application for DEHNventil?
The compact combined arrester shows its strengths above all in industrial low-voltage switchgear installations. It provides lightning equipotential bonding and terminal equipment protection at the same time. In industrial networks with mains follow currents of up to 100 kA, it is used for class of LPS 1 to 4.
What changes are there with regard to the stub wiring when connecting DEHNventil M2?
For stub wiring with the maximum backup fuse, the previously required backup fuse of 315 A has been reduced to 250 A. This creates more space in the terminal compartment of low-voltage switchgear installations. Another advantage: Shorter cable lengths for connecting the combined arrester make it possible to use the smaller NH1 fuse switch disconnector instead of the previously required NH2 disconnector.
What changes are there with regard to the feed-through wiring when connecting DEHNventil M2?
Compared to the predecessor model, DEHNventil M2 has half the width. The usual through-wiring with double terminals is therefore no longer possible. If you prefer this type of connection, use STAK 25 (part. no. 952589) to safely conduct operating currents of up to 100 A.
What are the advantages of using the new DEHNventil compared to the previous version?
The new DEHNventil M2 offers these advantages:
- Half the width of DEHNventil M: 4 modules
- User-friendly mechanism for easy replacement of protection modules
- Single module: One module for the entire connection of the arrester
- Remote signalling always included
- Rotated installation possible: 180° rotation
- Max. backup fuse: 250 A – additional space savings thanks to smaller fuse switch disconnector NH1 (instead of NH2)
- 5 instead of 10 variants
- Type 1+2+3 combined arrester with RAC spark gap technology
Is the depicted sheet shown in the field of application with the PE connection available to purchase directly from DEHN?
No, this is an example of an installation tool. It is usually made by the switchgear manufacturers themselves and serves to simplify installation. If you require further information, please do not hesitate to contact us. You will find the contact details at the bottom of the page.
Do wire end ferrules have to be used to connect the DEHNventil M2?
No, connection and safe operation are possible without wire end ferrules thanks to the cage clamps used.
What does the value UOC mean? Why is this 6 kV?
DEHNventil M2 is a Type 1+2+3 combined arrester tested according to DIN EN 61643-11. Therefore, the respective value of the test voltage for the Type 3 test must also be shown. In this context, the UOC specification corresponds to the value of the Type 3 test voltage. This value is defined as the "open-circuit voltage of the hybrid generator at the connection point of the test specimen" and corresponds to 6 kV for DEHNventil M2.
What is the difference between Ifi and Isccr? How are these values related?
According to DIN EN 61643-11, the follow current extinguishing capability Ifi is the prospective short-circuit current that can be interrupted by the SPD independently and without disconnection. Ideally, this value should be greater than or equal to the short-circuit strength Isccr. This is the highest prospective short-circuit current of the electrical network for which the arrester is rated in conjunction with its specified arrestor disconnector (DIN EN 61643-11). DEHNventil M2 is able to automatically quench a follow current of up to 100 kArms (tested by VDE).
Up to what maximum short-circuit currents can DEHNventil M2 be used?
The DEHNventil M2 combined arrester can be used in switchgear with prospective short-circuit currents greater than 50 kArms (VDE tested). A further test has also shown that it can be used up to a maximum prospective short-circuit current of 100 kArms (220 kApeak).
Is an earthing connection from the DEHNventil M2 to the main earthing busbar and additionally to the protective conductor necessary?
The application and connection of surge arresters is regulated in DIN VDE 0100-534 (2016-10). Here, a connection to the protective conductor of the customer's system and additionally to the main earthing busbar/main earthing terminal is required for type 1 surge arresters. Both connections are shown in the picture. The protective conductor connection is made via the earthed mounting plate (right terminal on DEHNventil M2), the connection to the main earthing busbar (left-hand connection to the PE busbar).
Note: In industrial switchgear installations with cross-sections over 150 mm², a separate connection of the surge arrester to the main earthing bar can be dispensed with, as these are already connected with a connecting cable and a corresponding cross-section. This is also described in question 6 on page 21 of the German brochure on "Protection against surges in low-voltage systems" published by the Central Association of the German Electrical and Information Technology Trades (ZVEH).
Are there any corrosion problems with the mounting plate in connection with the copper busbar?
The mounting plate shown in the figure is not made of aluminium. It is made of tin-plated copper (Cu/gal Sn). Galvanically tin-plated components, such as copper cable lugs, are used for corrosion protection. Thus, the PE busbar (Cu) and the mounting plate (Cu/gal Sn) shown in the picture do not constitute a material combination that is susceptible to corrosion.
Do wire end ferrules have to be used to connect the remote signalling contact?
DIN EN 60999-1 applies to all screw and screwless clamp connections. The standard specifies that connections must be designed by the manufacturer so that all unprepared conductor types can be connected.
The clamps used in the remote signalling contacts and for connecting the DEHNventil M2 are so-called "cage clamps”. As full contact is ensured here even with stranded wires, we recommend connection without wire end ferrules. The connection example can also be found in our installation instructions. The installation instructions are provided with our DEHNventil M2 products.
Is DEHNventil also available for the 40 mm busbar system?
DEHNventil is also available for the 40 mm busbar system: The combined lightning current and surge arresters DEHNventil ZP TNC (Part No. 900 390) and DEHNventil ZP TT (Part No. 900 391) are specially designed for the 40mm busbar connection panel of the meter mounting board. The DEHNventil ZP can be used in buildings with external lightning protection with class of LPS I and II. For (residential) buildings with external lightning protection with class of LPS III/IV or for residential buildings without external lightning protection, our proven DEHNshield ZP product range, e.g. the DSH ZP 2 SG TT 255, can be used.
Downloads
Brochure | DEHNventil M2 | Extremely good - down to the finest detail. | .pdf 9.0 MB |
Flyer | DEHNventil M2 | Extremely good - down to the finest detail. | .pdf 1.1 MB |
Selection guide | Product selection | Lightning and surge protection | .pdf 1.5 MB |
Our services
We support your project right from the start: from the risk assessment to planning the earthing system and external lightning protection.
DEHNrisk – the future of lightning protection analysis
With DEHNrisk, you can determine the lightning risk for structures comprehensively, quickly and precisely. The Web-based application provides support in determining the lightning protection class and other necessary measures.
DEHN Engineering Services – complete lightning protection concepts from a single source
We create the entire lightning protection concept – from the risk analysis and earthing simulation to budget planning – all precisely tailored to your project and standard-compliant.
A holistic approach to surge protection
Always the right solution
We offer more: our solutions secure information technology and protect lives.

DEHN protects IT
We offer protection solutions for the hardware and data flow in data centres, logistics and industrial plants.